                  六氟化硫報警裝置

                  • 雙氣體sf6監測系統
                  雙氣體sf6監測系統
                  雙氣體sf6監測系統
                  一、概述:
                  六氟化硫氣體報警控制器是本公司開發的高新技術產品,采用高檔單片機作為控制管理核心。與本公司的二總線制氣體探測器相配接,組成功能強大的氣體報警監控系統。
                  該產品是嚴格按照GB16808-2008《可燃氣體報警控制器》設計而成。由于采用M-Bus總線結構形式,所以該系統的最大特點是信號傳輸距離遠,安裝方便,特別適合控制范圍比較大的應用場合;該系統工作穩定、可靠,抗干擾性強,是燃氣報警系統更新換代的理想產品。
                  該產品可廣泛應用于石油化工、人工煤氣、冶金、鋼鐵、煉焦、電力等存在可燃或有毒氣體的各個行業,是保證財產和人身安全的理想監測儀器。
                  二、主要特點:
                  1、大屏幕LCD液晶顯示、界面友好。
                  2、全中文指示、操作簡單。
                  3、直觀、準確地顯示現場的燃氣濃度及探測器狀態。
                  4、具有設備故障、濃度報警兩種聲光指示功能
                  5、具有自檢、自診斷功能。
                  6、具有故障、報警記憶、查閱功能。
                  7、具有節點自動搜索、軟件調零、軟件標定、報警點設置功能。
                  8、設有密碼,防止誤操作。
                  9、可以隨時設置、修改和查閱系統的各項參數。
                  10、具有主、備電轉換及欠壓保護功能。
                  11、具有內置2組報警接點輸出控制功能,聯動信號可手動、自動輸出。
                  12、具有日歷顯示及設置功能。
                  13、采用M-BUS通訊協議,傳輸數據可靠;功能強大,性能穩定。
                  14、采用單回路兩總線通訊,信號無極性連接設計,具有自動保護功能,系統抗干擾能力強,布線經濟,安裝調試方便。
                  15、RS485總線通訊接口(選配,標準Modbus/RTU協議)能實現與上位機控制系統聯網,實現探測器監控,大大提高可監控的及時性、準確性。
                  三、主要技術指標:
                  1、示值誤差:±5%FS
                  2、顯示方式:大屏幕LCD液晶、發光管
                  3、報警方式:聲、光報警
                  4、報警音量:>75dB
                  5、響應時間:≤30s
                  6、工作電壓:主電:AC220V±15%,50Hz±1%
                               備電:12VDC/1.3Ah兩節
                  7、外形尺寸:320mm×230mm×90mm  
                  8、工作方式:連續
                  9、工作環境:溫度 -10℃—50℃   濕度 ≤93%RH
                               大氣壓力 86kPa—106kPa 
                  10、絕緣電阻:正常環境時 ≥100MΩ
                                濕度為93%RH時 ≥1MΩ
                  11、功    耗:小于10W
                  12、供電節點:4個、8個、16個
                  13、報警輸出:3A /2組 接點輸出,其中一組可設置脈沖輸出
                  14、信號傳輸:24V無極性兩總線(≥RVS 2*2.5mm2二芯雙絞線)
                  15、傳輸距離:<1200m
                  16、安裝方式:非防爆場合的壁掛式安裝
                  四、工作原理SF6http://www.qitijianlouyi.com/
                  控制器以M-Bus標準信號的方式接收探測器的氣體濃度信號;控制器接收到信號后,經過處理、邏輯分析、運算,以液晶數字顯示、聲光報警的方式反應出來,聯動接出繼電器,從而啟動所連接的風機、磁閥或其它消防設備。
                  五、安裝和接線
                  1、控制器的安裝
                  a、安裝位置
                  非防爆安全場所,其安裝位置應選擇在值班室或經常有人員出入的地方。安裝高度選擇方便操作即可,一般距地面1.4米處。
                  b、安裝方法
                  用兩個M5的自攻螺絲把掛架緊固在墻壁上,把控制器掛在掛架上。安裝要牢固,不傾斜,安裝尺寸如圖所示。(單位:mm)
                                                           控制器的外形結構圖
                  2、接線示意圖
                   
                  3、接線標識
                  標  識 說  明
                  RS485接口 RS485總線輸出接口,上傳系統A+、B-。
                  T+探測器T- 探測器接口(T+、T-),連接時無極性區分。
                  聯動1 NO1(常開),COM1(公共),NC1(常閉)信號無源輸出。開關量輸出
                  容量3A/250VAC或3A/30 VDC
                  聯動2 NO2(常開),COM2(公共), NC2(常閉)信號無源輸出。脈沖(瞬間):拔掉MC(COM2繼電器旁邊)短路子,動作時間為2S。容量3A/250VAC或3A/30 VDC
                  +備電- 備用電源接口(+ 接電池正極、- 接電池負極),
                  備電開關 備電電源開關
                  主電開關 主電電源開關
                  AC220V市電 主電源輸入,L、N分別接AC220V的火線和零線。
                  注意:接好線后,仔細檢查各種接線,確保接線正確后,再開啟電源。禁止帶電接線!
                  六、操作使用說明
                  控制器通電,打開主、備電開關(有備電電源時),預熱(3-5)分鐘后,系統進入正常監控狀態畫面(圖6-1)。
                   
                   
                   
                   
                   
                   
                   
                   
                   
                  圖6-1
                  6.1、液晶顯示內容介紹:
                   
                  標識 說  明
                  1、公司商標 公司LOGO標志
                  2、首警地址 第一個發生報警的地址
                  3、報警總數 發生濃度報警的探測器總數,“復位”后可清除。
                  4、主機地址 上傳圖型裝置或DCS系統的主機地址號
                  5、報警狀態 當探測器發生濃度報警時的狀態,“低報”、“高報”
                  6、單位 可燃顯示%LEL、毒性顯示ppm、氧氣等顯示%VOL
                  7、濃度值 當前探測器的實時濃度值或狀態
                  正常通訊:顯示≥000的數值
                  通訊故障:E0/  E1 / E2  
                            E0 當前探測器未連接好
                            E1 當前地址探測器傳感器故障
                            E2 當前地址探測器通訊故障
                  8、數值 特殊裝下會顯示
                  9、故障總數 發生故障報警的探測器總數,“復位”后可清除。
                  10、故障地址 發生故障時,故障地址循環滾動顯示,“復位”后可清除。
                  11、報警地址 發生濃度報警的地址。多路濃度報警時,報警地址循環滾動顯示,“復位”后可清除。
                  12、巡檢地址 巡視當前探測器地址
                   
                  提示:預熱完畢,如初次調試,應手動搜索(自搜)一遍節點。
                   
                  6.2、操作步驟:
                  輸入密碼方式:巡檢顯示界面下按“功能”鍵 通過“▲”或“▼”調整數值,通過“”或“”移位。   90s的操作時間,90s后自動退出(數據不存儲)。
                  按下“取消”鍵,自動退出(數據不存儲)
                  序號 操  作 密  碼 方法
                  1 “消音” 直接按下“消音”鍵,系統消音
                  2 “復位”
                  “1-1-1-1” 按下“功能”鍵  》》  輸入密碼 - - - -  
                  》》  再次按下“復位”鍵。釋放聯動接點、解除報警指示。
                  3 “自動搜索” “0-0-0-0” 按“功能”鍵  》》  輸入密碼 - - - -  
                  》》  再次按下“確認”鍵,系統自動搜索探測器  
                  4 “報警點”設置 “2-2-2-2” 修改報警點:
                  按“功能”鍵  》》  輸入密碼 - - - -  
                  》》 “”、“”鍵選“巡檢地址”,“▲”、“▼”設置當前地址的低報值 … …“低報”字樣顯示
                  再次按下“功能”鍵,“高報”字樣顯示  按“▲”、“▼”設置當前地址的高報值 … …
                  按“確定”鍵,顯示“good”,數據修改成功
                  5 時間調整設置
                  “秒”、“分”、“時” 、“日”、“月”、“年” “0-0-1-0” 時間調整(秒、分、時、日、月、年):
                  按“功能”鍵  》》  輸入密碼 - - - -  
                  再次按下“確定”鍵,“秒”閃爍  》》  “▲”、“▼”調整數值  
                  》》  依次按下按“”、“”鍵,“分”、“時”、“日”、“月”、“年”閃爍,“▲”、“▼”調整數值 … …
                  設置完畢后,按下“確定”鍵,顯示“good”存儲退出。 
                  不存儲,按“取消”鍵退出!
                  6 “聯動1” “3-3-3-3” 聯動1:按“功能”鍵  》》  輸入密碼 - - - -
                  按下“確定” 顯示“-ON-”,輸出COM1、NO(常開)吸合;
                  按“▼” 顯示“-OF-”, 再按下“確定”輸出COM1、NO(常開)斷開;此界面可循環交替進行手動控制輸出。
                  7 “聯動2” “4-4-4-4” 聯動2:按“功能”鍵  》》  輸入密碼 - - - -
                  按下“確定” 顯示“-ON-”,輸出COM2、NO(常開)吸合;
                  按“▼”顯示“-OF-”, 再按下“確定”輸出COM2、NO(常開)斷開;此界面可循環交替進行手動控制輸出。
                  注:需瞬間或脈沖輸出,請拔掉COM2端右邊的MC短路子
                  8 “自檢” “0-0-1-1” 按下“功能”鍵  》》  輸入密碼 - - - -  
                  》》  按“確定”鍵,再次按“自檢” 鍵控制器自檢。
                  9 “修改探測器地址” “0-0-6-5” 按“功能”鍵  》》  輸入密碼 - - - -  
                  》》  按下“確定”鍵,左邊顯示“原地址”,右邊顯示“新地址”》》 按 “▲”、“▼”鍵調整“新地址 ”“”、“”調整“原地址”, 》》  按“確定”鍵,顯示“good”,地址修改成功
                  操作完畢后按“取消”鍵退出!
                  10 “查詢”
                  (報警記錄) “6-6-6-6” 查詢(報警記錄):
                  按“功能”鍵  》》  輸入密碼 - - - -  
                  》》  按下“確定”鍵,顯示“報警地址”、“報警記錄”  
                  》》 “▲”、“▼”鍵可翻閱查看報警記錄;
                  按下“取消”退出操作!
                  11 “探測器啟用”設置 “0-0-5-5” 按“功能”鍵  》》  輸入密碼 - - - -  
                  》》  按下“確定”鍵,進入設置“巡檢地址”   
                  》》“”、“”鍵設定“巡檢地址”; “▲”、“▼”鍵選擇開啟(-ON-)或關閉(-OF-)
                  按“確定” 鍵,顯示“good”,數據成功保存!
                  按“取消”鍵,數據不保存退出操作!
                  12 “探測器校零” “0-0-6-2” 按“功能” 鍵, 》》  輸入密碼 - - - -  
                  》》  按下“確定”鍵,顯示當前“巡檢地址”的零點濃度值,  
                  》》 “▼”、“▲”切換巡檢地址;
                  按下“確定” 鍵為校準當前“巡檢地址”零點值。
                  按下“取消” 鍵退出。
                  注:為保證準確精度,請選擇潔靜的空氣環境進行校零,校零后請再標定一次。
                  13 “探測器標定” “0-0-6-0” 按“功能”鍵, 》》  輸入密碼 - - - -  
                  》》按下“確定”鍵,顯示當前“巡檢地址”的濃度值,  
                  》》 “”、“”切換巡檢地址;按“▲”、“▼”鍵選擇與標準氣的標定值。
                  按下“確定”鍵 標定當前“巡檢地址”。
                  按下“取消”鍵退出。
                  注:標準氣的流量不大于500ml/min,專用的標氣罩
                  14 “備電開啟” “9-9-9-9” 開啟或關閉備電檢測 按“功能” 鍵, 》》  輸入密碼 - - - -  》》按下“確定”鍵進入。按“▼”鍵選擇-ON-或-OF-,開啟與關閉.按“確定”鍵,數據保存并退出!
                  15 “查看報警點” “0-0-2-2” 按“功能”鍵  》》  輸入密碼 - - - -  
                  》》按 “”、“”鍵選擇要查看的探測器地址,按“確定”鍵查看,顯示“Errr”說明查看錯誤,再重新按確定鍵查看,按“功能”鍵,可進行交替查看當前地址的報警設定值 …。
                  查看完畢后按“取消”鍵退出!
                   
                   
                   
                   
                   
                   
                  七、產品維護
                  ⑴控制器應安裝在值班室或經常有人員出入的場所,應有專人監管;用戶和非專業人員不許隨意拆卸儀器。
                  ⑵控制器在正常監控狀態下,請勿經常斷電。
                  ⑶應定期檢查控制器是否正常工作,周期建議每三個月一次。
                  ⑷請勿隨意更改控制器內部參數,以免參數不匹配影響正常使用。
                  ⑸如有故障維修需要拆下時,請先確認控制器斷電。
                  ⑹設備運輸存貯時,應避免劇烈震動。
                  ⑺儀器自購買之日起保修一年(自然災害和人為因素除外),終生服務。
                  八、故障診斷及排除:
                  當控制器發出故障報警信號時,值班人員應首先進行“消音”操作,后根據所報故障地址、故障類型, 對照以下表格進行處理
                  故障現象 原因分析 處理方法
                  “E0” 當前地址探測器沒有接好 對當前探測器重新檢查接線
                  “E1” 當前地址探測器傳感器故障 檢查或更換傳感器
                  “E2” 當前地址探測器通訊故障 檢查探測器的連接線是否有脫落、松動。
                  所有探測器顯示“E2” 連接探測器的線路短路或斷路 檢查總線線路,有短路或斷路地方存在
                  打開主電開關,系統不運行 外電沒接通電源
                  保險管未裝或保險絲斷 檢查電源線是否接好
                  打開保險管盒,裝上保險管
                  提示:1、探測器T+、T-接好后,確保兩線之間不短路、不斷路。首次開機后進行手動自搜一次,若出現“巡檢地址”顯示為空,“濃度值”顯示為空,即探測器線路未接好,請重新檢查接線,完事后,再搜一次,重復進行直到正常為止。
                  2、如出現報故障現象,請查閱上表中故障現象說明。
                  九、面板圖及功能說明:
                   
                  (1)、指示燈說明:
                   
                   
                   
                   
                   
                  系統狀態燈
                  運行 該燈閃爍,說明系統軟件循環檢測運行中。
                  報警 系統總報警指示燈,當任一只探測器檢測到的氣體濃度高于報警設定值時,該指示燈點亮,且一直鎖定,直至“復位”鍵按下解除。
                  故障 系統總故障指示燈,系統任何一處有故障,該指示燈點亮。
                  電源狀態燈
                  主電 正常該燈發綠色,說明系統主電源供電正常。
                  主電故障 該燈發黃色,說明系統未接通主電AC220V。
                  備電 正常該燈發綠色,說明系統備用電源運行正常。
                  備電故障 該燈發黃色,說明系統未接通備用電源。
                  充電故障 該燈發黃色,說明備電充電回路短路或斷路。
                  ⑵、按鍵說明
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                  復位 控制器“報警”狀態取消,聯動設備復位
                  消音 在警報或故障狀態下,按下“消音”鍵可中止音響,若再次發生警報時,揚聲器再次發出警報聲音。
                  功能 參數設置(具體詳見  操作)
                  減、查詢報警
                  加、控制器自檢
                  位選
                  位選、鎖定顯示
                  確認 進入設置界面或保存設置結果。(具體詳見  操作)
                  取消 在非實時界面下,按“取消”鍵。不保存退出返回到系統實時界面。
                  (3)、顯示窗口
                  顯示控制器的所有信息。(具體詳見操作使用說明6.1)
                   
                   
                   
                   
                   
                   
                   
                   
                   
                  目   錄
                   
                  一、概述··························································1
                  二、主要特點····················································1
                  三、主要技術指標···············································2
                  四、工作原理·····················································2
                  五、安裝和接線·················································3
                  六、操作使用說明··············································4
                  七、產品維護·····················································8
                  八、故障診斷及排除···········································8
                  九、面板圖及功能說明········································9
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                  使用安裝說明書
                   
                   
                   
                  六氟化硫氣體報警控制器
                   
                   
                   
                        
                  “微信號”          
                   
                   
                   
                  濟南東信電子科技有限公司
                  為正確的使用本設備,請在使用前仔細閱讀本說明書,并妥善保管以供今后參考。
                   
                   
                  濟南東信電子科技有限公司
                  JiNan DongXin Electronic Technology Co., Ltd.       
                   
                  地址:山東·濟南
                  郵政編碼:250000
                  客戶服務電話:0531-85828303
                  公司官方網站:http://www.cixicdyy.com/
                   
                   
                  6 “聯動1” “3-3-3-3” 聯動1:按“功能”鍵  》》  輸入密碼 - - - -
                  按下“確定” 顯示“-ON-”,輸出COM1、NO(常開)吸合;
                  按“▼” 顯示“-OF-”, 再按下“確定”輸出COM1、NO(常開)斷開;此界面可循環交替進行手動控制輸出。
                  7 “聯動2” “4-4-4-4” 聯動2:按“功能”鍵  》》  輸入密碼 - - - -
                  按下“確定” 顯示“-ON-”,輸出COM2、NO(常開)吸合;
                  按“▼”顯示“-OF-”, 再按下“確定”輸出COM2、NO(常開)斷開;此界面可循環交替進行手動控制輸出。
                  注:需瞬間或脈沖輸出,請拔掉COM2端右邊的MC短路子
                  8 “自檢” “0-0-1-1” 按下“功能”鍵  》》  輸入密碼 - - - -  
                  》》  按“確定”鍵,再次按“自檢” 鍵控制器自檢。
                  9 “修改探測器地址” “0-0-6-5” 按“功能”鍵  》》  輸入密碼 - - - -  
                  》》  按下“確定”鍵,左邊顯示“原地址”,右邊顯示“新地址”》》 按 “▲”、“▼”鍵調整“新地址 ”“”、“”調整“原地址”, 》》  按“確定”鍵,顯示“good”,地址修改成功
                  操作完畢后按“取消”鍵退出!
                  10 “查詢”
                  (報警記錄) “6-6-6-6” 查詢(報警記錄):
                  按“功能”鍵  》》  輸入密碼 - - - -  
                  》》  按下“確定”鍵,顯示“報警地址”、“報警記錄”  
                  》》 “▲”、“▼”鍵可翻閱查看報警記錄;
                  按下“取消”退出操作!
                  11 “探測器啟用”設置 “0-0-5-5” 按“功能”鍵  》》  輸入密碼 - - - -  
                  》》  按下“確定”鍵,進入設置“巡檢地址”   
                  》》“”、“”鍵設定“巡檢地址”; “▲”、“▼”鍵選擇開啟(-ON-)或關閉(-OF-)
                  按“確定” 鍵,顯示“good”,數據成功保存!
                  按“取消”鍵,數據不保存退出操作!
                  12 “探測器校零” “0-0-6-2” 按“功能” 鍵, 》》  輸入密碼 - - - -  
                  》》  按下“確定”鍵,顯示當前“巡檢地址”的零點濃度值,  
                  》》 “▼”、“▲”切換巡檢地址;
                  按下“確定” 鍵為校準當前“巡檢地址”零點值。
                  按下“取消” 鍵退出。
                  注:為保證準確精度,請選擇潔靜的空氣環境進行校零,校零后請再標定一次。
                  13 “探測器標定” “0-0-6-0” 按“功能”鍵, 》》  輸入密碼 - - - -  
                  》》按下“確定”鍵,顯示當前“巡檢地址”的濃度值,  
                  》》 “”、“”切換巡檢地址;按“▲”、“▼”鍵選擇與標準氣的標定值。
                  按下“確定”鍵 標定當前“巡檢地址”。
                  按下“取消”鍵退出。
                  注:標準氣的流量不大于500ml/min,專用的標氣罩
                  14 “備電開啟” “9-9-9-9” 開啟或關閉備電檢測 按“功能” 鍵, 》》  輸入密碼 - - - -  》》按下“確定”鍵進入。按“▼”鍵選擇-ON-或-OF-,開啟與關閉.按“確定”鍵,數據保存并退出!
                  15 “查看報警點” “0-0-2-2” 按“功能”鍵  》》  輸入密碼 - - - -  
                  》》按 “”、“”鍵選擇要查看的探測器地址,按“確定”鍵查看,顯示“Errr”說明查看錯誤,再重新按確定鍵查看,按“功能”鍵,可進行交替查看當前地址的報警設定值 …。
                  查看完畢后按“取消”鍵退出!
                   
                   
                   
                   
                   
                   
                  七、產品維護
                  ⑴控制器應安裝在值班室或經常有人員出入的場所,應有專人監管;用戶和非專業人員不許隨意拆卸儀器。
                  ⑵控制器在正常監控狀態下,請勿經常斷電。
                  ⑶應定期檢查控制器是否正常工作,周期建議每三個月一次。
                  ⑷請勿隨意更改控制器內部參數,以免參數不匹配影響正常使用。
                  ⑸如有故障維修需要拆下時,請先確認控制器斷電。
                  ⑹設備運輸存貯時,應避免劇烈震動。
                  ⑺儀器自購買之日起保修一年(自然災害和人為因素除外),終生服務。
                  八、故障診斷及排除:
                  當控制器發出故障報警信號時,值班人員應首先進行“消音”操作,后根據所報故障地址、故障類型, 對照以下表格進行處理
                  故障現象 原因分析 處理方法
                  “E0” 當前地址探測器沒有接好 對當前探測器重新檢查接線
                  “E1” 當前地址探測器傳感器故障 檢查或更換傳感器
                  “E2” 當前地址探測器通訊故障 檢查探測器的連接線是否有脫落、松動。
                  所有探測器顯示“E2” 連接探測器的線路短路或斷路 檢查總線線路,有短路或斷路地方存在
                  打開主電開關,系統不運行 外電沒接通電源
                  保險管未裝或保險絲斷 檢查電源線是否接好
                  打開保險管盒,裝上保險管
                  提示:1、探測器T+、T-接好后,確保兩線之間不短路、不斷路。首次開機后進行手動自搜一次,若出現“巡檢地址”顯示為空,“濃度值”顯示為空,即探測器線路未接好,請重新檢查接線,完事后,再搜一次,重復進行直到正常為止。
                  2、如出現報故障現象,請查閱上表中故障現象說明。
                  九、面板圖及功能說明:
                   
                  (1)、指示燈說明:
                   
                   
                   
                   
                   
                  系統狀態燈
                  運行 該燈閃爍,說明系統軟件循環檢測運行中。
                  報警 系統總報警指示燈,當任一只探測器檢測到的氣體濃度高于報警設定值時,該指示燈點亮,且一直鎖定,直至“復位”鍵按下解除。
                  故障 系統總故障指示燈,系統任何一處有故障,該指示燈點亮。
                  電源狀態燈
                  主電 正常該燈發綠色,說明系統主電源供電正常。
                  主電故障 該燈發黃色,說明系統未接通主電AC220V。
                  備電 正常該燈發綠色,說明系統備用電源運行正常。
                  備電故障 該燈發黃色,說明系統未接通備用電源。
                  充電故障 該燈發黃色,說明備電充電回路短路或斷路。
                  ⑵、按鍵說明
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                  復位 控制器“報警”狀態取消,聯動設備復位
                  消音 在警報或故障狀態下,按下“消音”鍵可中止音響,若再次發生警報時,揚聲器再次發出警報聲音。
                  功能 參數設置(具體詳見  操作)
                  減、查詢報警
                  加、控制器自檢
                  位選
                  位選、鎖定顯示
                  確認 進入設置界面或保存設置結果。(具體詳見  操作)
                  取消 在非實時界面下,按“取消”鍵。不保存退出返回到系統實時界面。
                  (3)、顯示窗口
                  顯示控制器的所有信息。(具體詳見操作使用說明6.1)
                   
                   
                   
                   
                   
                   
                   
                   
                   
                  目   錄
                   
                  一、概述··························································1
                  二、主要特點····················································1
                  三、主要技術指標···············································2
                  四、工作原理·····················································2
                  五、安裝和接線·················································3
                  六、操作使用說明··············································4
                  七、產品維護·····················································8
                  八、故障診斷及排除···········································8
                  九、面板圖及功能說明········································9
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                  使用安裝說明書
                   
                   
                   
                  六氟化硫氣體報警控制器
                   
                   
                   
                        
                  “微信號”          
                   
                   
                   
                  濟南東信電子科技有限公司
                  為正確的使用本設備,請在使用前仔細閱讀本說明書,并妥善保管以供今后參考。
                   
                   
                  濟南東信電子科技有限公司
                  JiNan DongXin Electronic Technology Co., Ltd.       
                   
                  地址:山東·濟南
                  郵政編碼:250000
                  客戶服務電話:0531-85828303
                  公司官方網站:http://www.cixicdyy.com/
                   
                   
                   
                  一、概述··························································1
                  二、主要特點····················································1
                  三、主要技術指標···············································2
                  四、工作原理·····················································2
                  五、安裝和接線·················································3
                  六、操作使用說明··············································4
                  七、產品維護·····················································8
                  八、故障診斷及排除···········································8
                  九、面板圖及功能說明········································9
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                   
                  使用安裝說明書
                   
                   
                   
                  六氟化硫氣體報警控制器
                   
                   
                   
                        
                  “微信號”          
                   
                   
                   
                  濟南東信電子科技有限公司
                  為正確的使用本設備,請在使用前仔細閱讀本說明書,并妥善保管以供今后參考。
                   
                   
                  濟南東信電子科技有限公司
                  JiNan DongXin Electronic Technology Co., Ltd.       
                   
                  地址:山東·濟南
                  郵政編碼:250000
                  客戶服務電話:0531-85828303
                  公司官方網站:http://www.cixicdyy.com/
                   
                   
                  六氟化硫報警器是我公司科研人員根據市場需求與多家科研機構聯合研制成功的新一代高科技電子產品,報警探測器是按照GB15322-2003《氣體探測器技術要求及試驗方法》嚴格設計制造,探測器內的檢測傳感器采用進口傳感器作為檢測元件,靈敏度高,響應速度塊,當報警器探測到環境中的六氟化硫氣體濃度達到或超過預設置報警點時,控制主機立即發出聲光報警,同時可啟動排風裝置,已達到安全之目的。

                  聯系我們

                  公司名稱: 濟南東信電子科技有限公司

                  手 機: 15376190119

                  電 話: 濟南高新技術開發區

                  郵 箱: 365871495@qq.com

                  地 址: 365871495

                  亚洲爱综合网站_看久久久久久一级毛片_婷婷久久综合九色综合97_明星乱亚洲合成图com